LSZH

Home / Products / Materials

HZD2720-EV

HZD2720-EV is an oil-resistant 125°C irradiation cross-linked LSZH compound for EV and rolling-stock cable — passes the single-wire vertical flame test and meets GB 12528.11-2003, with verified oil and diesel immersion performance.

Blue cable compound pellet sample

Blue cable compound pellet sample

01 / 02
HZD2720-EV

Material — Oil-resistant irradiation cross-linked LSZH polyolefin compound

125CLSZHOil-resistantGB/T 18380.1 / UL 1581GB 12528.11-2003

Overview

HZD2720-EV is a 125°C halogen-free flame-retardant cable compound, colorable, built on a polyolefin base with inorganic flame retardants, antioxidants and lubricants, internally mixed, plasticized and pelletized. It offers outstanding oil resistance and flexibility together with good mechanical strength and elongation, and passes the single-wire vertical flame test.

The grade targets applications with demanding oil exposure — typically rolling-stock and vehicle cable — and satisfies the requirements of GB 12528.11-2003. Oil immersion performance is verified in 20# machine oil (100°C × 70 h) and 0# diesel (70°C × 168 h); see the property table. A factory inspection report for this 125°C polyolefin EV grade is available on request.

Packaging & Storage

Supplied in aluminum-plastic bags with kraft paper lining, 25 kg net per bag. Store in a dry, well-ventilated warehouse.

Product family
Materials
Reference
HZD2720-EV
Applications
4 documented
Published data
20 rows

Grade qualification

Validate the grade against the cable, process and target standard

Published properties establish the review baseline. Cable construction, processing conditions and a line trial complete the grade decision.

Cable compound extrusion machine in the production workshop
Real production equipment used in the compound preparation and pelletizing route.
  1. 01

    Define the duty profile

    Confirm cable construction, operating temperature, flame class and environmental requirements.

  2. 02

    Review the published data

    Match requirements, typical values and test methods to the finished-cable target.

  3. 03

    Run a controlled line trial

    Set drying, temperature, screw and irradiation conditions from the grade processing card.

  4. 04

    Approve the production window

    Record surface, dimensions, mechanical results and finished-cable tests before volume production.

Inquiry input

Send these four details

  • 01Cable construction
  • 02Target standard
  • 03Color and quantity
  • 04Extrusion line details

Technical data

Typical Properties

Review requirement, typical production value and test method together. The official TDS defines the binding supply specification.

Density
1.53 g/cm³

Typical value

Tensile strength
11.8 MPa

Typical value

Elongation at break
168 %

Typical value

Oxygen index
42 %

Typical value

PropertyUnitRequirementTypicalTest Method
Densityg/cm³≤ 1.601.53GB 1033
Tensile strengthMPa≥ 911.8GB 1040
Elongation at break%≥ 125168GB 1040
Thermal aging°C × h158 × 168158 × 168GB 2951.7
Tensile strength retention after aging%≥ 70107GB 2951.7
Elongation retention after aging%≥ 7095GB 2951.7
Volume resistivity (20°C)Ω·m≥ 1×10¹²5.71×10¹²GB 1410
Dielectric strengthMV/m≥ 2529GB 1408
Oxygen index%≥ 3542GB 2406
Smoke density (flaming)≤ 10087GB 8323
Smoke density (non-flaming)≤ 180150GB 8323
Oil immersion — tensile change (20# oil, 100°C × 70 h)%≤ 5025GB/T 2951.5
Oil immersion — elongation change (20# oil, 100°C × 70 h)%≤ 5011GB/T 2951.5
Diesel immersion — tensile change (0# diesel, 70°C × 168 h)%≤ 5535GB/T 2951.5
Diesel immersion — elongation change (0# diesel, 70°C × 168 h)%≤ 5518GB/T 2951.5
Toxicity index≤ 51.8NES 713
pH≥ 4.36.1GB/T 17650.2
ConductivityμS/mm≤ 102.7GB/T 17650.2
Single-wire vertical flame testPassGB/T 18380.1 / UL 1581
Shore hardness A77GB 2411

* Typical values are measured on production samples and provided for reference only — they are not a specification guarantee. Request the official TDS for binding limits.

Application & process

Connect the product data to production

Application requirements and processing conditions are reviewed together before sample approval and production supply.

Connected feeding and pelletizing system for cable compounds
Feeding, transfer and pellet handling are controlled as one production process.

Use cases

Documented applications

  1. 01EV and new-energy vehicle cable
  2. 02Rolling stock and locomotive cable (GB 12528.11-2003)
  3. 03Oil-exposed industrial equipment wiring
  4. 04Flexible cable insulation and jackets

Process notes

Processing recommendations

  1. 01Recommended equipment: φ45–150 single-screw extruder, L/D ≥ 20, screen pack 20/80/20 mesh
  2. 02A dedicated halogen-free screw with compression ratio below 2.5 improves output and surface quality
  3. 03Temperature profile: feed 110°C / transport 125°C / melting 140°C / die 140–150°C — trim die temperature to wire surface finish
  4. 04Irradiation dose: 150–180 kGy (15–18 Mrad)

Inquiry

Send your inquiry for HZD2720-EV

Send your cable standard, target temperature rating and quantity to request HZD2720-EV samples or quotation.

  • 01Cable construction
  • 02Target standard
  • 03Color and quantity
  • 04Extrusion line details

Tell us your cable spec.

Temperature rating, flame standard, processing method — send your requirements and get grade recommendations plus line matching within one working day.